Verified HISS Results from Four Recovery Boilers
Heat Management's HISS (High Impact Sootblowing System) has demonstrated reductions of over 30% in sootblowing steam consumption at four black liquor recovery boilers, while maintaining or increasing boiler load. These results are based on actual operating data collected directly from the facilities, comparing recovery boiler load and sootblowing steam consumption before and after HISS implementation. Facility 1 – 31% Reduction in Sootblowing Steam Consumption Following the implementation of HISS, the recovery boiler achieved: Boiler load: Increased by 6.3%, from 1,200 to 1,275 tDS/day. Sootblowing steam consumption: Reduced by 31%, from 14.5 to 10 t/h. Facility 2 – 30.4% Reduction in Sootblowing Steam Consumption The second recovery boiler achieved significant steam savings alongside increased boiler load: Boiler load: Increased by 4.15%, from 2,050 to 2,135 tDS/day. Sootblowing steam consumption: Reduced by 30.4%, from 21.7 to 15.1 t/h. Facility 3 – 33.3% Reduction at Stable Boiler Load At the third recovery boiler, HISS delivered substantial steam savings while maintaining the [...]