{"id":1612,"date":"2021-01-07T13:50:32","date_gmt":"2021-01-07T13:50:32","guid":{"rendered":"https:\/\/heatmanage.com\/?p=1612"},"modified":"2021-01-07T13:52:02","modified_gmt":"2021-01-07T13:52:02","slug":"metodo-eficaz-de-limpeza-online-para-caldeiras-de-tubos-de-fumaca-urbanos","status":"publish","type":"post","link":"https:\/\/heatmanage.com\/pt\/smoke-tube-boiler\/effective-on-line-cleaning-method-for-urbas-smoke-tube-boilers\/","title":{"rendered":"M\u00e9todo eficaz de limpeza online para caldeiras Urbas com tubos de fuma\u00e7a"},"content":{"rendered":"<p><strong>Em plantas de aquecimento de at\u00e9 25 MWth, uma forma econ\u00f4mica e compacta de recuperar a energia no g\u00e1s de combust\u00e3o quente \u00e9 atrav\u00e9s do uso de um caldeir\u00e3o de tubos de fuma\u00e7a. Como o nome sugere, num caldeir\u00e3o de tubos de fuma\u00e7a, o g\u00e1s de combust\u00e3o passa por tubos, rodeados por um revestimento de \u00e1gua que resfria os tubos de fuma\u00e7a. Os caldeiros s\u00e3o normalmente montados verticalmente e geralmente possuem tr\u00eas passagens de tubos, com entre 300 e 800 tubos dentro do caldeir\u00e3o, variando de quente no centro para frio nas partes externas.<\/strong><\/p>\n<p>A limpeza online de caldeiras de tubos de fuma\u00e7a \u00e9 um desafio e deve ser combinada com a limpeza manual. Os m\u00e9todos tradicionais de limpeza incluem a aspira\u00e7\u00e3o de ar comprimido a partir do topo da caldeira e a limpeza manual de cada tubo. Para a limpeza manual, a caldeira deve ser desligada e normalmente \u00e9 utilizada uma caldeira a g\u00e1s para compensar a perda de produ\u00e7\u00e3o. A limpeza manual \u00e9 um trabalho perigoso que pode levar at\u00e9 um dia e custar tanto em horas de trabalho quanto em consumo de \u00f3leo.<\/p>\n<p>A maioria das vezes, a obstru\u00e7\u00e3o de um caldeir\u00e3o de tubos de fuma\u00e7a come\u00e7a na c\u00e2mara de rota\u00e7\u00e3o inferior, onde n\u00e3o h\u00e1 limpeza autom\u00e1tica e onde o ar comprimido que sopra da parte superior n\u00e3o chega. O mecanismo de obstru\u00e7\u00e3o inclui a acumula\u00e7\u00e3o do chamado \u201cbarbejo\u201d na entrada dos tubos de fuma\u00e7a. \u00c0 medida que o barbear cresce, ele \u00e9 sugado para dentro dos tubos e acaba por obstru\u00ed-los. Como cada tubo constitui 0,5 % da \u00e1rea de transfer\u00eancia de calor do sistema, a transfer\u00eancia de calor \u00e9 rapidamente deteriorada, resultando em perdas de efici\u00eancia t\u00e9rmica. Utilizando infra-som de longo alcance, os tubos de fuma\u00e7a s\u00e3o mantidos abertos na parte inferior, evitando essas perdas e prolongando o tempo entre as interven\u00e7\u00f5es manuais de limpeza.<\/p>\n<div id=\"attachment_1614\" style=\"width: 898px\" class=\"wp-caption alignnone\"><img decoding=\"async\" aria-describedby=\"caption-attachment-1614\" class=\"wp-image-1614 size-full\" src=\"https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.26.45.png\" alt=\"Limpeza do caldeir\u00e3o de tubos de fuma\u00e7a\" width=\"888\" height=\"852\" srcset=\"https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.26.45-200x192.png 200w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.26.45-300x288.png 300w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.26.45-400x384.png 400w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.26.45-600x576.png 600w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.26.45-768x737.png 768w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.26.45-800x768.png 800w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.26.45.png 888w\" sizes=\"(max-width: 888px) 100vw, 888px\" \/><p id=\"caption-attachment-1614\" class=\"wp-caption-text\">Fig. 1. Caldeira de tubos de fuma\u00e7a de passagem vertical, com tubos de fuma\u00e7a superiores (parte superior) e impurezas na c\u00e2mara de combust\u00e3o inferior (parte inferior)<\/p><\/div>\n<h2>Um limpador de infra-som padr\u00e3o<\/h2>\n<p>Heat Management Desenvolveu um limpador de infra-som padr\u00e3o para esse prop\u00f3sito, que n\u00e3o exige um modelo ac\u00fastico completo e possui um design gen\u00e9rico para cada instala\u00e7\u00e3o. O resultado \u00e9 o fornecimento econ\u00f4mico de um limpador de infra-som potente para todos os caldeiros com tubos de fuma\u00e7a. O limpador de infra-som \u00e9 acionado por uma v\u00e1lvula solen\u00f3ide de 24 V DC e funciona com ar comprimido (6 a 8 bar), por dois segundos a cada quatro minutos, e um sensor de press\u00e3o sonora fornece a sa\u00edda ac\u00fastica do limpador de infra-som, entre 25 e 40 kPa. O consumo de ar varia de 6 a 9 Nm3\/h, dependendo do tamanho (MWth) do caldeir\u00e3o. \u00c9 necess\u00e1rio instalar um tanque de reserva de 500 litros pr\u00f3ximo ao limpador de infra-som.<\/p>\n<h2>Refer\u00eancias de instala\u00e7\u00f5es anteriores<\/h2>\n<p>Heat Management H\u00e1 muitas refer\u00eancias e estudos de caso sobre este tipo de caldeira. Os resultados t\u00edpicos para essas refer\u00eancias s\u00e3o uma redu\u00e7\u00e3o no n\u00famero de paradas para limpeza manual, uma redu\u00e7\u00e3o na carga m\u00e9dia do ventilador de gases de combust\u00e3o e uma redu\u00e7\u00e3o na temperatura m\u00e9dia da sa\u00edda de gases de combust\u00e3o.<\/p>\n<p><strong><a href=\"https:\/\/heatmanage.com\/pt\/documentos-de-estudos-de-caso\/?tex_application=smoke-tube-boiler&amp;tex_product=infra&amp;tex_portfolio_category=case-studies\">Saiba mais sobre nossas instala\u00e7\u00f5es anteriores<\/a><\/strong><\/p>\n<h2>Instala\u00e7\u00e3o geral do limpador de infra-som<\/h2>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-1619\" src=\"https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.24-min.png\" alt=\"\" width=\"1234\" height=\"956\" srcset=\"https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.24-min-200x155.png 200w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.24-min-300x232.png 300w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.24-min-400x310.png 400w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.24-min-600x465.png 600w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.24-min-768x595.png 768w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.24-min-800x620.png 800w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.24-min-1024x793.png 1024w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.24-min-1200x930.png 1200w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.24-min.png 1234w\" sizes=\"(max-width: 1234px) 100vw, 1234px\" \/> <img decoding=\"async\" class=\"alignnone size-full wp-image-1620\" src=\"https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.37-min.png\" alt=\"\" width=\"1208\" height=\"466\" srcset=\"https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.37-min-200x77.png 200w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.37-min-300x116.png 300w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.37-min-400x154.png 400w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.37-min-600x231.png 600w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.37-min-768x296.png 768w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.37-min-800x309.png 800w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.37-min-1024x395.png 1024w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.37-min-1200x463.png 1200w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.37-min.png 1208w\" sizes=\"(max-width: 1208px) 100vw, 1208px\" \/> <img decoding=\"async\" class=\"alignnone size-full wp-image-1621\" src=\"https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.47-min.png\" alt=\"\" width=\"1250\" height=\"922\" srcset=\"https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.47-min-200x148.png 200w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.47-min-300x221.png 300w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.47-min-400x295.png 400w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.47-min-600x443.png 600w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.47-min-768x566.png 768w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.47-min-800x590.png 800w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.47-min-1024x755.png 1024w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.47-min-1200x885.png 1200w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.47-min.png 1250w\" sizes=\"(max-width: 1250px) 100vw, 1250px\" \/><\/p>","protected":false},"excerpt":{"rendered":"<p>Heat Management has developed a standard infrasound cleaner for smoke tube boilers &#8211; The result is the cost-efficient supply of a powerful infrasound cleaner for all smoke tube boilers.<\/p>","protected":false},"author":1,"featured_media":1613,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"content-type":"","footnotes":""},"categories":[61],"tags":[],"class_list":["post-1612","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-smoke-tube-boiler"],"_links":{"self":[{"href":"https:\/\/heatmanage.com\/pt\/wp-json\/wp\/v2\/posts\/1612","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/heatmanage.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/heatmanage.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/heatmanage.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/heatmanage.com\/pt\/wp-json\/wp\/v2\/comments?post=1612"}],"version-history":[{"count":6,"href":"https:\/\/heatmanage.com\/pt\/wp-json\/wp\/v2\/posts\/1612\/revisions"}],"predecessor-version":[{"id":1624,"href":"https:\/\/heatmanage.com\/pt\/wp-json\/wp\/v2\/posts\/1612\/revisions\/1624"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/heatmanage.com\/pt\/wp-json\/wp\/v2\/media\/1613"}],"wp:attachment":[{"href":"https:\/\/heatmanage.com\/pt\/wp-json\/wp\/v2\/media?parent=1612"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/heatmanage.com\/pt\/wp-json\/wp\/v2\/categories?post=1612"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/heatmanage.com\/pt\/wp-json\/wp\/v2\/tags?post=1612"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}