{"id":5075,"date":"2026-10-22T13:38:12","date_gmt":"2026-10-22T11:38:12","guid":{"rendered":"https:\/\/heatmanage.com\/?p=5075"},"modified":"2026-10-22T13:39:00","modified_gmt":"2026-10-22T11:39:00","slug":"vahvistetut-hoyryntuotokset-neljalta-talteenotto-uunilta","status":"publish","type":"post","link":"https:\/\/heatmanage.com\/fi\/news\/verified-hiss-results-from-four-recovery-boilers\/","title":{"rendered":"Vahvistetut HISS-tulokset nelj\u00e4st\u00e4 talteenottolaitteesta"},"content":{"rendered":"<p data-pm-slice=\"1 1 []\"><strong>Heat Management\u2019s HISS (<a href=\"https:\/\/heatmanage.com\/fi\/ratkaisut\/optimoitu-hoyrynoenpoisto\/\">Korkean iskun savupurkausj\u00e4rjestelm\u00e4<\/a>) on osoittanut yli 30 prosentin v\u00e4hennyksen savunpoistol\u00e4mmityksen savup\u00e4\u00e4st\u00f6iss\u00e4 nelj\u00e4ss\u00e4 musta\u00f6ljyj\u00e4 hy\u00f6dynt\u00e4v\u00e4ss\u00e4 kattilassa s\u00e4ilytt\u00e4en samalla kattilakonetta tai kasvattamalla sit\u00e4.<\/strong><\/p>\n<p>N\u00e4m\u00e4 tulokset perustuvat suoraan laitoksista ker\u00e4ttyihin tosiasiallisiin k\u00e4ytt\u00f6dataan ja vertaavat hy\u00f6tys\u00e4hk\u00f6n polttoaineen kulutusta ja savunpoistolaitteiden h\u00f6yrykulutusta ennen ja j\u00e4lkeen HISS-j\u00e4rjestelm\u00e4n k\u00e4ytt\u00f6\u00f6noton.<\/p>\n<p>&nbsp;<\/p>\n<h2 data-pm-slice=\"1 1 []\"><span style=\"color: #008080;\">Laitos 1 \u2013 31% Pienentynyt savunpoistopatterin savup\u00e4\u00e4st\u00f6jen m\u00e4\u00e4r\u00e4<\/span><\/h2>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-5086\" src=\"https:\/\/heatmanage.com\/wp-content\/uploads\/2026\/10\/Facility_1_Results_Table.png\" alt=\"\" width=\"290\" height=\"88\" srcset=\"https:\/\/heatmanage.com\/wp-content\/uploads\/2026\/10\/Facility_1_Results_Table-18x5.png 18w, https:\/\/heatmanage.com\/wp-content\/uploads\/2026\/10\/Facility_1_Results_Table-200x61.png 200w, https:\/\/heatmanage.com\/wp-content\/uploads\/2026\/10\/Facility_1_Results_Table.png 290w\" sizes=\"(max-width: 290px) 100vw, 290px\" \/><\/p>\n<h3 data-pm-slice=\"1 1 []\"><\/h3>\n<p data-pm-slice=\"1 3 []\">HISS-j\u00e4rjestelm\u00e4n k\u00e4ytt\u00f6\u00f6noton j\u00e4lkeen talteenotto-allas saavutti seuraavat tulokset:<\/p>\n<ul data-spread=\"false\">\n<li><strong>Kattilak\u00e4ytt\u00f6:<\/strong> Kasvua 6,3 prosenttia, 1 200:sta 1 275:een tDS\/p\u00e4iv\u00e4ss\u00e4.<\/li>\n<li><strong>Savup\u00f6lynpoistoilman kulutus:<\/strong> Pienentynyt 31%:st\u00e4 14,5:st\u00e4 tuntiin 10 t\/h.<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p><img decoding=\"async\" class=\"alignnone wp-image-5085\" src=\"https:\/\/heatmanage.com\/wp-content\/uploads\/2026\/10\/Facility_1_Operational_Trend_Chart.png\" alt=\"\" width=\"515\" height=\"342\" srcset=\"https:\/\/heatmanage.com\/wp-content\/uploads\/2026\/10\/Facility_1_Operational_Trend_Chart-18x12.png 18w, https:\/\/heatmanage.com\/wp-content\/uploads\/2026\/10\/Facility_1_Operational_Trend_Chart-200x133.png 200w, https:\/\/heatmanage.com\/wp-content\/uploads\/2026\/10\/Facility_1_Operational_Trend_Chart-300x199.png 300w, https:\/\/heatmanage.com\/wp-content\/uploads\/2026\/10\/Facility_1_Operational_Trend_Chart-400x266.png 400w, https:\/\/heatmanage.com\/wp-content\/uploads\/2026\/10\/Facility_1_Operational_Trend_Chart-600x398.png 600w, https:\/\/heatmanage.com\/wp-content\/uploads\/2026\/10\/Facility_1_Operational_Trend_Chart.png 717w\" sizes=\"(max-width: 515px) 100vw, 515px\" \/><\/p>\n<hr \/>\n<h2 data-pm-slice=\"1 3 []\"><\/h2>\n<h2 data-pm-slice=\"1 3 []\"><span style=\"color: #008080;\">Laitos 2 \u2013 30.4% Pienentynyt savup\u00e4\u00e4st\u00f6tilavuuden kulutus<\/span><\/h2>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-5088\" src=\"https:\/\/heatmanage.com\/wp-content\/uploads\/2026\/10\/Facility_2_Results_Table.png\" alt=\"\" width=\"288\" height=\"84\" srcset=\"https:\/\/heatmanage.com\/wp-content\/uploads\/2026\/10\/Facility_2_Results_Table-18x5.png 18w, https:\/\/heatmanage.com\/wp-content\/uploads\/2026\/10\/Facility_2_Results_Table-200x58.png 200w, https:\/\/heatmanage.com\/wp-content\/uploads\/2026\/10\/Facility_2_Results_Table.png 288w\" sizes=\"(max-width: 288px) 100vw, 288px\" \/><\/p>\n<p>Toinen talteenotto-uuni tuotti merkitt\u00e4vi\u00e4 h\u00f6yrys\u00e4\u00e4st\u00f6j\u00e4 samalla kun kattilan kuormitus kasvoi:<\/p>\n<ul data-spread=\"false\">\n<li><strong>Kattilak\u00e4ytt\u00f6:<\/strong> Kasvussa 4,15%, 2 050:sta 2 135 tDS\/p\u00e4iv\u00e4\u00e4n.<\/li>\n<li><strong>Savup\u00f6lynpoistoilman kulutus:<\/strong> Pienentynyt 30,4 prosentilla, 21,7 t\/h:sta 15,1 t\/h:een.<\/li>\n<\/ul>\n<h1><img decoding=\"async\" class=\"alignnone wp-image-5087\" src=\"https:\/\/heatmanage.com\/wp-content\/uploads\/2026\/10\/Facility_2_Operational_Trend_Chart.png\" alt=\"\" width=\"523\" height=\"351\" srcset=\"https:\/\/heatmanage.com\/wp-content\/uploads\/2026\/10\/Facility_2_Operational_Trend_Chart-18x12.png 18w, https:\/\/heatmanage.com\/wp-content\/uploads\/2026\/10\/Facility_2_Operational_Trend_Chart-200x134.png 200w, https:\/\/heatmanage.com\/wp-content\/uploads\/2026\/10\/Facility_2_Operational_Trend_Chart-300x201.png 300w, https:\/\/heatmanage.com\/wp-content\/uploads\/2026\/10\/Facility_2_Operational_Trend_Chart-400x268.png 400w, https:\/\/heatmanage.com\/wp-content\/uploads\/2026\/10\/Facility_2_Operational_Trend_Chart-600x403.png 600w, https:\/\/heatmanage.com\/wp-content\/uploads\/2026\/10\/Facility_2_Operational_Trend_Chart.png 720w\" sizes=\"(max-width: 523px) 100vw, 523px\" \/><\/h1>\n<hr \/>\n<h2 data-pm-slice=\"1 3 []\"><\/h2>\n<h2 data-pm-slice=\"1 3 []\"><span style=\"color: #008080;\">Laitos 3 \u2013 33,3% V\u00e4hennys vakaassa kattilak\u00e4yt\u00f6ss\u00e4<\/span><\/h2>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-5090\" src=\"https:\/\/heatmanage.com\/wp-content\/uploads\/2026\/10\/Facility_3_Results_Table.png\" alt=\"\" width=\"284\" height=\"89\" srcset=\"https:\/\/heatmanage.com\/wp-content\/uploads\/2026\/10\/Facility_3_Results_Table-18x6.png 18w, https:\/\/heatmanage.com\/wp-content\/uploads\/2026\/10\/Facility_3_Results_Table-200x63.png 200w, https:\/\/heatmanage.com\/wp-content\/uploads\/2026\/10\/Facility_3_Results_Table.png 284w\" sizes=\"(max-width: 284px) 100vw, 284px\" \/><\/p>\n<p>Kolmannessa talteenotto-uunissa HISS saavutti merkitt\u00e4vi\u00e4 h\u00f6yrys\u00e4\u00e4st\u00f6j\u00e4 s\u00e4ilytt\u00e4en samat kattolataukset:<\/p>\n<ul data-spread=\"false\">\n<li><strong>Kattilak\u00e4ytt\u00f6:<\/strong> Pysyi vakaana 1 131 tDS\/p\u00e4iv\u00e4n\u00e4.<\/li>\n<li><strong>Savup\u00f6lynpoistoilman kulutus:<\/strong> Pienentynyt 33,3 prosentilla, 14,1 t\/h:sta 9,4 t\/h:een.<\/li>\n<\/ul>\n<p><img decoding=\"async\" class=\"alignnone wp-image-5089\" src=\"https:\/\/heatmanage.com\/wp-content\/uploads\/2026\/10\/Facility_3_Operational_Trend_Chart.png\" alt=\"\" width=\"548\" height=\"366\" srcset=\"https:\/\/heatmanage.com\/wp-content\/uploads\/2026\/10\/Facility_3_Operational_Trend_Chart-18x12.png 18w, https:\/\/heatmanage.com\/wp-content\/uploads\/2026\/10\/Facility_3_Operational_Trend_Chart-200x134.png 200w, https:\/\/heatmanage.com\/wp-content\/uploads\/2026\/10\/Facility_3_Operational_Trend_Chart-300x200.png 300w, https:\/\/heatmanage.com\/wp-content\/uploads\/2026\/10\/Facility_3_Operational_Trend_Chart-400x267.png 400w, https:\/\/heatmanage.com\/wp-content\/uploads\/2026\/10\/Facility_3_Operational_Trend_Chart-600x401.png 600w, https:\/\/heatmanage.com\/wp-content\/uploads\/2026\/10\/Facility_3_Operational_Trend_Chart.png 723w\" sizes=\"(max-width: 548px) 100vw, 548px\" \/><\/p>\n<hr \/>\n<h2 data-pm-slice=\"1 3 []\"><\/h2>\n<h2 data-pm-slice=\"1 3 []\"><span style=\"color: #008080;\">Laitos 4 \u2013 31.3% Pienentynyt savup\u00e4\u00e4st\u00f6tilavuuden kulutus<\/span><\/h2>\n<p><img decoding=\"async\" class=\"alignnone wp-image-5092\" src=\"https:\/\/heatmanage.com\/wp-content\/uploads\/2026\/10\/Facility_4_Results_Table.png\" alt=\"\" width=\"324\" height=\"93\" srcset=\"https:\/\/heatmanage.com\/wp-content\/uploads\/2026\/10\/Facility_4_Results_Table-18x5.png 18w, https:\/\/heatmanage.com\/wp-content\/uploads\/2026\/10\/Facility_4_Results_Table-200x57.png 200w, https:\/\/heatmanage.com\/wp-content\/uploads\/2026\/10\/Facility_4_Results_Table-300x86.png 300w, https:\/\/heatmanage.com\/wp-content\/uploads\/2026\/10\/Facility_4_Results_Table-350x100.png 350w, https:\/\/heatmanage.com\/wp-content\/uploads\/2026\/10\/Facility_4_Results_Table-400x115.png 400w, https:\/\/heatmanage.com\/wp-content\/uploads\/2026\/10\/Facility_4_Results_Table.png 411w\" sizes=\"(max-width: 324px) 100vw, 324px\" \/><\/p>\n<p>Nelj\u00e4s talteenotto-uuni tuotti samankaltaisia tuloksia, yhdist\u00e4m\u00e4ll\u00e4 alhaisemman h\u00f6yrykulutuksen ja suuremman uunilatauksen:<\/p>\n<ul data-spread=\"false\">\n<li><strong>Kattilak\u00e4ytt\u00f6:<\/strong> Kasvua 7,8 prosenttia, 2 431:st\u00e4 2 621 tonnia p\u00e4iv\u00e4ss\u00e4.<\/li>\n<li><strong>Savup\u00f6lynpoistoilman kulutus:<\/strong> Pienentynyt 31,3% tonnilla, 25,9 tonnista 17,8 tonniin\/h.<\/li>\n<\/ul>\n<h1><img decoding=\"async\" class=\"alignnone wp-image-5091\" src=\"https:\/\/heatmanage.com\/wp-content\/uploads\/2026\/10\/Facility_4_Operational_Trend_Chart.png\" alt=\"\" width=\"574\" height=\"385\" srcset=\"https:\/\/heatmanage.com\/wp-content\/uploads\/2026\/10\/Facility_4_Operational_Trend_Chart-18x12.png 18w, https:\/\/heatmanage.com\/wp-content\/uploads\/2026\/10\/Facility_4_Operational_Trend_Chart-200x134.png 200w, https:\/\/heatmanage.com\/wp-content\/uploads\/2026\/10\/Facility_4_Operational_Trend_Chart-300x201.png 300w, https:\/\/heatmanage.com\/wp-content\/uploads\/2026\/10\/Facility_4_Operational_Trend_Chart-400x268.png 400w, https:\/\/heatmanage.com\/wp-content\/uploads\/2026\/10\/Facility_4_Operational_Trend_Chart-600x402.png 600w, https:\/\/heatmanage.com\/wp-content\/uploads\/2026\/10\/Facility_4_Operational_Trend_Chart.png 713w\" sizes=\"(max-width: 574px) 100vw, 574px\" \/><\/h1>\n<hr \/>\n<h3 data-pm-slice=\"1 1 []\">T\u00e4rkeint\u00e4 oli, ett\u00e4 kukaan nelj\u00e4st\u00e4 laitteesta ei tarvinnut lis\u00e4ty\u00f6kaluja, apulaitteita tai muutoksia nykyisiin ohjauslaitteisiin.<\/h3>\n<h2 data-pm-slice=\"1 1 []\"><span style=\"color: #008080;\">Lis\u00e4energia- ja toiminnalliset edut<\/span><\/h2>\n<p data-pm-slice=\"1 1 []\">Sootinpoistol\u00e4mm\u00f6n kulutuksen suoran v\u00e4henemisen lis\u00e4ksi HISS voi parantaa kokonaisenergian talteenotto-tehokkuutta seuraavilla tavoilla:<\/p>\n<ul data-spread=\"false\">\n<li><strong>Tehokkaamman h\u00f6yryjen tuotannon lis\u00e4\u00e4minen:<\/strong> Tehokkaamman l\u00e4mm\u00f6nsiirtopintojen puhdistus parantaa l\u00e4mm\u00f6nsiirtoa ja voi lis\u00e4t\u00e4 h\u00f6yryntuotantoa.<\/li>\n<li><strong>Pienempi kattiloiden veden sy\u00f6tt\u00f6m\u00e4\u00e4r\u00e4:<\/strong> Alhaisempi h\u00f6yrykysynt\u00e4 savunpoistoon v\u00e4hent\u00e4\u00e4 k\u00e4sitellyn kattilaveden lis\u00e4ystarvetta.<\/li>\n<\/ul>\n<p>N\u00e4iden lis\u00e4hy\u00f6tyjen avulla voidaan parantaa asennuksen yleist\u00e4 taloudellista tehokkuutta entisest\u00e4\u00e4n.<\/p>\n<p>&nbsp;<\/p>\n<h2><span style=\"color: #008080;\">Suorituskyky takaa takuita<\/span><\/h2>\n<p>Heat Management yhdist\u00e4\u00e4 osoitetut operatiiviset tulokset sopimuksellisten suorituskykyvarmistusten kanssa.<\/p>\n<p>N\u00e4ihin takuisiin kuuluu kattilan k\u00e4ytett\u00e4vyyden yll\u00e4pit\u00e4minen tai parantaminen sek\u00e4 <strong>v\u00e4hint\u00e4\u00e4n 30 prosentin v\u00e4hennys savup\u00f6lynpoistoon k\u00e4ytett\u00e4v\u00e4n h\u00f6yryn kulutuksessa<\/strong>, josta voi synty\u00e4 jopa 50 prosentin s\u00e4\u00e4st\u00f6j\u00e4 kattilan ominaisuuksista ja k\u00e4ytt\u00f6olosuhteista riippuen.<\/p>\n<p>HISS tarjoaa my\u00f6s mahdollisuuden lis\u00e4t\u00e4 pakokaasujen puhallusvoimakkuutta jopa 100 prosentilla s\u00e4ilytt\u00e4en samalla sopimukseen perustuvat suorituskykyvaatimukset kattilan k\u00e4ytt\u00f6i\u00e4n ja h\u00f6yrykulutuksen osalta.<\/p>\n<p>Edell\u00e4 mainitut takuut ovat ehdottomia, Heat Management ja investoinnin koko hinta hyvitet\u00e4\u00e4n takaisin, jos taattuja tuloksia ei saavuteta.<\/p>\n<p>&nbsp;<\/p>\n<h2><span style=\"color: #008080;\">Todistetut tulokset ja mitattavissa olevat s\u00e4\u00e4st\u00f6t<\/span><\/h2>\n<p>N\u00e4iden nelj\u00e4n mustan likan talteenotto-ilmal\u00e4mp\u00f6laitteen tulokset osoittavat, kuinka HISS voi pienent\u00e4\u00e4 pakokaasup\u00e4\u00e4st\u00f6jen vuoksi vapautuva h\u00f6yrykulutusta <strong>30\u201333%<\/strong>, Samalla kun kattilan kuormitus s\u00e4ilytet\u00e4\u00e4n tai jopa lis\u00e4t\u00e4\u00e4n.<\/p>\n<p>Toimintaolosuhteista, paikallisista kustannuksista ja investointivaatimuksista riippuen takaisinmaksuaika voi olla alle 12 kuukautta.<\/p>\n<p>Kun hyv\u00e4ksytyt toiminnalliset parannukset yhdistet\u00e4\u00e4n sopimusperusteisiin suorituskykyvarmuuteen, Heat Management saavutetaan savunpoistoj\u00e4rjestelmien optimointi, joka on mitattavissa talteenotto-kattilan tehokkuuden ja suorituskyvyn parantamiseksi.<\/p>\n<p>&nbsp;<\/p>\n<blockquote><p>Lue lis\u00e4\u00e4 HISS Advanced -j\u00e4rjestelm\u00e4st\u00e4 ja siit\u00e4, miten se v\u00e4hent\u00e4\u00e4 h\u00f6yrykulutusta ja kattiloiden putkien rappeutumista, k\u00e4y sivustollamme <strong><a href=\"https:\/\/heatmanage.com\/fi\/ratkaisut\/optimoitu-hoyrynoenpoisto\/\"><span style=\"color: #3366ff;\"><span style=\"color: #008080;\">HISS-ratkaisut-sivusto<\/span><\/span><\/a><\/strong>.<\/p>\n<p>&nbsp;<\/p>\n<p data-pm-slice=\"1 1 []\">Lis\u00e4tietoja n\u00e4ist\u00e4 tapauksista tai siit\u00e4, kuinka HISS voi parantaa tuhkapurkauskyky\u00e4 tehtaallanne, voit ottaa meihin yhteytt\u00e4. <a href=\"https:\/\/heatmanage.com\/fi\/ota-yhteytta\/\">Ota yhteytt\u00e4<\/a> t\u00e4n\u00e4\u00e4n.<\/p>\n<\/blockquote>","protected":false},"excerpt":{"rendered":"<p>Heat Management&#8217;s HISS (High Impact Sootblowing System) has demonstrated reductions of over 30% in sootblowing steam consumption at four black liquor recovery boilers, while maintaining or increasing boiler load. These results are based on actual operating data collected directly from the facilities, comparing recovery boiler load and sootblowing steam consumption before and after HISS implementation. &nbsp; Facility 1 \u2013 31% Reduction in Sootblowing Steam Consumption Following the implementation of HISS, the recovery boiler achieved: Boiler load: Increased by 6.3%, from 1,200 to 1,275 tDS\/day. Sootblowing steam consumption: Reduced by 31%, from 14.5 to 10 t\/h. &nbsp; Facility 2 \u2013 30.4% Reduction in Sootblowing Steam Consumption The second recovery boiler achieved significant steam savings alongside increased boiler load: Boiler load: Increased by 4.15%, from 2,050 to 2,135 tDS\/day. Sootblowing steam consumption: Reduced by 30.4%, from 21.7 to 15.1 t\/h. Facility 3 \u2013 33.3% Reduction at Stable Boiler Load At the third recovery boiler, HISS delivered substantial steam savings while maintaining the  [&#8230;]<\/p>\n","protected":false},"author":12,"featured_media":5096,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"content-type":"","footnotes":""},"categories":[53,1,51,65],"tags":[],"class_list":["post-5075","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news","category-knowledge","category-optimized-steam-sootblowing-articles","category-recovery-boilers"],"_links":{"self":[{"href":"https:\/\/heatmanage.com\/fi\/wp-json\/wp\/v2\/posts\/5075","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/heatmanage.com\/fi\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/heatmanage.com\/fi\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/heatmanage.com\/fi\/wp-json\/wp\/v2\/users\/12"}],"replies":[{"embeddable":true,"href":"https:\/\/heatmanage.com\/fi\/wp-json\/wp\/v2\/comments?post=5075"}],"version-history":[{"count":5,"href":"https:\/\/heatmanage.com\/fi\/wp-json\/wp\/v2\/posts\/5075\/revisions"}],"predecessor-version":[{"id":5098,"href":"https:\/\/heatmanage.com\/fi\/wp-json\/wp\/v2\/posts\/5075\/revisions\/5098"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/heatmanage.com\/fi\/wp-json\/wp\/v2\/media\/5096"}],"wp:attachment":[{"href":"https:\/\/heatmanage.com\/fi\/wp-json\/wp\/v2\/media?parent=5075"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/heatmanage.com\/fi\/wp-json\/wp\/v2\/categories?post=5075"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/heatmanage.com\/fi\/wp-json\/wp\/v2\/tags?post=5075"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}