{"id":1612,"date":"2021-01-07T13:50:32","date_gmt":"2021-01-07T13:50:32","guid":{"rendered":"https:\/\/heatmanage.com\/?p=1612"},"modified":"2021-01-07T13:52:02","modified_gmt":"2021-01-07T13:52:02","slug":"effektiv-metode-til-online-rengoring-af-urbas-rogrorskedler","status":"publish","type":"post","link":"https:\/\/heatmanage.com\/da\/smoke-tube-boiler\/effective-on-line-cleaning-method-for-urbas-smoke-tube-boilers\/","title":{"rendered":"Effektiv on-line reng\u00f8ringsmetode til Urbas r\u00f8gr\u00f8rskedler"},"content":{"rendered":"<p><strong>I varmecentraler p\u00e5 op til 25 MWth er en omkostningseffektiv og kompakt m\u00e5de at genvinde energien i den varme r\u00f8ggas p\u00e5 at anvende en r\u00f8gkanalkedel. Som navnet antyder, passerer r\u00f8ggasen i en r\u00f8gkanalkedel inde i r\u00f8r, omgivet af en vandmantel, der afk\u00f8ler r\u00f8gkanalerne. Kedlerne monteres normalt lodret og har generelt tre r\u00f8rgange med mellem 300 og 800 r\u00f8r inde i kedel, der sp\u00e6nder fra varme i midten til kolde i de ydre dele.<\/strong><\/p>\n<p>Online-reng\u00f8ring af r\u00f8gr\u00f8rskedler er en udfordring og skal desuden kombineres med manuel reng\u00f8ring. Traditionelle reng\u00f8ringsmetoder omfatter trykluftbl\u00e6sning fra toppen af kedlen samt manuel reng\u00f8ring af hvert enkelt r\u00f8r. Ved manuel reng\u00f8ring skal kedlen tages ud af drift, og normalt anvendes en oliefyret kedel til at kompensere for produktionstabet. Manuel reng\u00f8ring er et farligt arbejde, der kan tage op til en dag og koster b\u00e5de mandetimer og olieforbrug.<\/p>\n<p>Mest almindeligt starter tilfodingen af en r\u00f8gr\u00f8rskedel i det nederste vendekammer, hvor der ikke er nogen automatisk reng\u00f8ring, og hvor den trykluft, der bl\u00e6ser fra toppen, ikke n\u00e5r ned. Tilsmudsningsmekanismen omfatter akkumulering af et s\u00e5kaldt \u201csk\u00e6g\u201d ved indl\u00f8bet til r\u00f8gr\u00f8rene. Efterh\u00e5nden som sk\u00e6gget vokser, suges det ind i r\u00f8rene og tilstopper dem til sidst. Da hvert r\u00f8r udg\u00f8r 0,5 % af passagefladen for varmeoverf\u00f8rsel, forringes varmeoverf\u00f8rslen hurtigt, hvilket resulterer i tab af termisk virkningsgrad. Ved hj\u00e6lp af infralyd med lang r\u00e6kkevidde holdes r\u00f8gr\u00f8rene \u00e5bne i bunden, hvorved n\u00e6vnte tab undg\u00e5s, og tiden mellem driftsstop for manuel reng\u00f8ring forl\u00e6nges.<\/p>\n<div id=\"attachment_1614\" style=\"width: 898px\" class=\"wp-caption alignnone\"><img decoding=\"async\" aria-describedby=\"caption-attachment-1614\" class=\"wp-image-1614 size-full\" src=\"https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.26.45.png\" alt=\"Reng\u00f8ring af r\u00f8gr\u00f8rskedel\" width=\"888\" height=\"852\" srcset=\"https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.26.45-200x192.png 200w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.26.45-300x288.png 300w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.26.45-400x384.png 400w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.26.45-600x576.png 600w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.26.45-768x737.png 768w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.26.45-800x768.png 800w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.26.45.png 888w\" sizes=\"(max-width: 888px) 100vw, 888px\" \/><p id=\"caption-attachment-1614\" class=\"wp-caption-text\">Fig 1. Vertikal to-pass r\u00f8gr\u00f8rskedel med \u00f8vre r\u00f8gr\u00f8r (\u00f8verst) og tilsmudsning i det nederste vendekammer (nederst)<\/p><\/div>\n<h2>En standard infralydsrenser<\/h2>\n<p>Heat Management har udviklet en standardinfralydrenser til dette form\u00e5l, som ikke kr\u00e6ver en fuldst\u00e6ndig akustisk model, og som har et generisk design til hver enkelt installation. Resultatet er en omkostningseffektiv levering af en kraftfuld infralydrenser til alle r\u00f8gr\u00f8rskedler. Infralydrenseren betjenes med en 24 V DC-magnetventil og k\u00f8rer p\u00e5 trykluft (6-8 bar) i to sekunder hvert fjerde minut, og en lydtryksf\u00f8ler angiver infralydrenserens akustiske effekt p\u00e5 mellem 25 og 40 kPa. Luftforbruget varierer fra 6 til 9 Nm3\/h afh\u00e6ngigt af kedlens st\u00f8rrelse (MWth). Der skal installeres en buffertank p\u00e5 500 liter t\u00e6t p\u00e5 infralydrenseren.<\/p>\n<h2>Referencer fra tidligere installationer<\/h2>\n<p>Heat Management har masser af referencer og casestudier for denne kedeltype. Typiske resultater for referencerne er et reduceret antal stop for manuel reng\u00f8ring, reduceret gennemsnitlig belastning af r\u00f8ggasventilatoren og reduceret gennemsnitlig r\u00f8ggasafgangstemperatur.<\/p>\n<p><strong><a href=\"https:\/\/heatmanage.com\/da\/casestudier-dokumenter\/?tex_application=smoke-tube-boiler&amp;tex_product=infra&amp;tex_portfolio_category=case-studies\">F\u00e5 mere at vide om vores tidligere installationer<\/a><\/strong><\/p>\n<h2>Generel installation af infrasound-renser<\/h2>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-1619\" src=\"https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.24-min.png\" alt=\"\" width=\"1234\" height=\"956\" srcset=\"https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.24-min-200x155.png 200w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.24-min-300x232.png 300w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.24-min-400x310.png 400w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.24-min-600x465.png 600w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.24-min-768x595.png 768w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.24-min-800x620.png 800w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.24-min-1024x793.png 1024w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.24-min-1200x930.png 1200w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.24-min.png 1234w\" sizes=\"(max-width: 1234px) 100vw, 1234px\" \/> <img decoding=\"async\" class=\"alignnone size-full wp-image-1620\" src=\"https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.37-min.png\" alt=\"\" width=\"1208\" height=\"466\" srcset=\"https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.37-min-200x77.png 200w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.37-min-300x116.png 300w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.37-min-400x154.png 400w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.37-min-600x231.png 600w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.37-min-768x296.png 768w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.37-min-800x309.png 800w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.37-min-1024x395.png 1024w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.37-min-1200x463.png 1200w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.37-min.png 1208w\" sizes=\"(max-width: 1208px) 100vw, 1208px\" \/> <img decoding=\"async\" class=\"alignnone size-full wp-image-1621\" src=\"https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.47-min.png\" alt=\"\" width=\"1250\" height=\"922\" srcset=\"https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.47-min-200x148.png 200w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.47-min-300x221.png 300w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.47-min-400x295.png 400w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.47-min-600x443.png 600w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.47-min-768x566.png 768w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.47-min-800x590.png 800w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.47-min-1024x755.png 1024w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.47-min-1200x885.png 1200w, https:\/\/heatmanage.com\/wp-content\/uploads\/2021\/01\/Ska\u0308rmavbild-2021-01-07-kl.-14.38.47-min.png 1250w\" sizes=\"(max-width: 1250px) 100vw, 1250px\" \/><\/p>","protected":false},"excerpt":{"rendered":"<p>Heat Management has developed a standard infrasound cleaner for smoke tube boilers &#8211; The result is the cost-efficient supply of a powerful infrasound cleaner for all smoke tube boilers.<\/p>","protected":false},"author":1,"featured_media":1613,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"content-type":"","footnotes":""},"categories":[61],"tags":[],"class_list":["post-1612","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-smoke-tube-boiler"],"_links":{"self":[{"href":"https:\/\/heatmanage.com\/da\/wp-json\/wp\/v2\/posts\/1612","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/heatmanage.com\/da\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/heatmanage.com\/da\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/heatmanage.com\/da\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/heatmanage.com\/da\/wp-json\/wp\/v2\/comments?post=1612"}],"version-history":[{"count":6,"href":"https:\/\/heatmanage.com\/da\/wp-json\/wp\/v2\/posts\/1612\/revisions"}],"predecessor-version":[{"id":1624,"href":"https:\/\/heatmanage.com\/da\/wp-json\/wp\/v2\/posts\/1612\/revisions\/1624"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/heatmanage.com\/da\/wp-json\/wp\/v2\/media\/1613"}],"wp:attachment":[{"href":"https:\/\/heatmanage.com\/da\/wp-json\/wp\/v2\/media?parent=1612"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/heatmanage.com\/da\/wp-json\/wp\/v2\/categories?post=1612"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/heatmanage.com\/da\/wp-json\/wp\/v2\/tags?post=1612"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}